Maintenance Object Repair Procedures
555-233-123
10-252
Issue 4 May 2002
3
FAIL
Distorted tone returned
Test the active tone clock on the port network, and verify that a
tone is reaching the ATM-TRK circuit pack. If not, correct the
condition.
Run test board UUCSS long.
If the test continues to fail, replace the ATM-TRK circuit pack.
Run test board UUCSS long.
4
FAIL
Unable to create TDM-path loop.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Run test board UUCSS long.
5
FAIL
Unable to create packet-path loop.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Rerun test board UUCSS long.
6
FAIL
A previously established looparound was not released.
Run reset board UUCSS.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Rerun test board UUCSS long.
PASS
The non-optical parts of the ATM-TRK circuit pack are functioning
properly.
0
NO
BOARD
ATM-TRK circuit pack not found
Check the error log for Error 125 (wrong board) or Error 131 (no
board), and correct as necessary.
Check that the board is properly translated and inserted.
Check for Error 1538 (hyperactivity), and run reset board
UUCSS if necessary.
Rerun test board UUCSS long.
If the test fails, replace the board, and rerun test board UUCSS
long.
Table 10-102.
ATM Board Framer Looparound Test (#1260) — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...