DAT-LINE (Data Line)
Issue 4 May 2002
10-509
555-233-123
1004
ABORT
The port has been seized by a user for a valid call. Use status
data-module to determine when the port is available for
testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1020
ABORT
The test did not run due to an already existing error on this port
(Error Type 769).
1. Refer to the procedure for Error Type 769. If Error Type
769 still occurs on this port, replace the circuit pack.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated
using other port tests, examining the ADU, external wiring, and
customer equipment.
Table 10-186.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...