Maintenance Object Repair Procedures
555-233-123
10-1082
Issue 4 May 2002
Notes:
a. Error Type 1 - For the TN802B only, this error type indicates that less than
three DSPs are out of service (OOS), and no alarm is raised. The Aux Data
field contains the number of DSPs that are Out of Service (OOS).
b. Error Type 18 - the MEDPRO has been busied out by busyout port
UUCSS.
1. Release the port (release port UUCSS).
c. Error Type 258 - For the TN802B only, this error type indicates that more
than three, but less than 9 DSPs are out of service (OOS), and a
WARNING alarm is raised. The Aux Data field contains the number of
DSPs that are Out Of Service (OOS).
d. Error Type 513 - For the TN2302 only, the port is out of service (OOS)
because an associated DSP is bad.
e. Error Type 515 - For the TN802B only, this error type indicates that all
DSPs are out of service (OOS), and a MINOR alarm is raised. The Aux
Data field contains the number of DSPs that are Out Of Service (OOS).
f. Error Type 1025 - The port is out of service (OOS) because of a board
level failure. Check for errors/alarms against the board; in particular, ping
problems, IP address inconsistency, or board sanity problems.
1. Verify correct administration.
2. Check cabling and customer network before replacing circuit pack.
258(c)
ANY
DSP Capacity Test
(#1382)
WARNING
ON
test board UUCCSS l r5
513(d)
DSP Capacity Test
(#1382)
MINOR
ON
test port UUCCSSpp
515(e)
ANY
DSP Capacity Query
Test (##1382)
MINOR
ON
test board UUCCSS l r5
769
Any
TDM NIC
Looparound Test
(#1380)
MIN
ON
test port UUCCSS l r10
1025(f)
Any
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-405.
MEDPROPT Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...