This test is a basic connectivity test between the two cabinets. The test first sends
a test tone from the cabinet of the Expansion Interface circuit pack under test
through the opposite Expansion Interface circuit pack to a Tone Detector in the
opposite cabinet. The connections are then reversed and the tone is passed in the
opposite direction. This test should be run once from each Expansion Interface
circuit pack on the fiber.
PASS
Test tone was correctly detected after the internal Expansion
Interface loop back on both TDM Busses.
1. Refer to other Expansion Interface circuit pack tests if the
Expansion Interface Link is not functioning correctly.
0
NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board
(error 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If
so, check for hyperactivity (error 1538). If hyperactive, use
the reset board PCSS command.
3. Run the test again. If it fails, the ID chip on board may be bad.
Replace the board and retest.
Table 10-292.
TEST #241 Expansion Interface 2-Way Transmission Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Table 10-291.
TEST #240 EI Local Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...