Maintenance Object Repair Procedures
555-233-123
10-1574
Issue 4 May 2002
5. If the error of loss of handshake persists after the replacement of the
NetPkt or Netcon circuit pack, consider the replacement of the
control carrier. It’s possible that the M-Bus on the backplane of the
control carrier may be defective.
Recommended Repair Kits: Processor circuit pack
(TN2404/TN790) with correct software release and Memory Card
(J58890TG-1 List 3), NetPkt (TN2401/TN794) or Netcon (TN777B)
circuit pack.
f. The Aux Data for this error is not meaningful. The 1793 errors are in-line
errors that indicate a possible problem with the interface between the
Switch Control and the processor. The receipt of these errors causes
Switch Control maintenance to run specific Switch Control tests. If there
really is a problem, the Switch Control tests usually causes other errors to
be logged. In the rare case where no other errors are logged but 1793
errors are occurring at a high rate (more than 10 in the last hour), the
NetPkt or Netcon circuit pack should be replaced at the customer’s
convenience.
g. This error indicates bad clock detection circuitry on the NetPkt or Netcon
circuit pack. Replace the NetPkt or Netcon circuit pack according to the
control carrier circuit pack replacement procedures.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...