PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1393
555-233-123
10303
10310
ABORT
MTP did not respond to the test request.
1. Repeat test at 1-minute intervals a maximum of 5 times.
2. If only the MTP Analog Loop Around Test is aborting,
escalate the problem.
3. If all MTP tests are aborting, execute the test processor
a/b long command in order to reset MTP, and examine the
results of the MTP Reset Test (#101).
10305
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
10306
ABORT
System could not determine if the testing of the INADS port is
administered.
1. Enter change system-parameters maintenance
command, and verify the entry for the Test Remote Access
Port field.
2. Retry the command at 1-minute intervals a maximum of 5
times.
10308
ABORT
The remote access port is busy. INADS is probably dialed into
the switch.
1. Wait until INADS session is terminated and then re-enter
the command.
10311
ABORT
Test #102 MTP Outpulse Relay Test failed.
1. Refer to Error Code 10204 of the MTP Outpulse Relay
Test (#102) for directions.
10304
FAIL
MTP reported test failure. The system is not able to reliably
contact INADS with alarm data. The system continues to
provide good service.
1. If MTP Outpulse Relay Test (#102) is also failing, check for
the presence of the INADS trunk, and resolve any INADS
trunk problems.
2. If Test #102 passes, the fault is on the Processor circuit
pack. The circuit pack should be replaced at your
convenience.
PASS
MTP detected correct data through the loop back connection.
1. If the system cannot call INADS, or if INADS cannot
contact the system, check with the local Central Office for
problems with the INADS trunk, and verify that the INADS
number is correct.
Table 10-517.
TEST #103 MTP Analog Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...