Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-248
Issue 4 May 2002
Output
The following output example displays recycle carrier c.
Field descriptions
refresh route-table
Occasionally the tables used to route IP messages become corrupted and/or
contain stale routes, delaying packet delivery. This command removes all
dynamic (learned) routes from the TN799 (C-LAN) circuit pack’s route tables and
replaces any of the stale (administered) routes that have become corrupted.
NOTE:
This command is call-preserving, so the switch does not drop any calls
already in service.
Port
Port address (cabinet-carrier) for tested maintenance objects. This
field displays cabinet and carrier values.
Maintenance
Name
CARR-POW.
Alt. Name
Not applicable.
Test Number
T126.
Test Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
refresh
route-table
all
location
Refreshes all C-LAN circuit
packs in a switch
Refreshes the route tables in a
specific C-LAN circuit pack
(CCcss)
init
inads
craft
station and trunk
MSP permissions
recycle carrier c
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C CARR-POW 126 PASS
Command successfully completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...