Maintenance Object Repair Procedures
555-233-123
10-606
Issue 4 May 2002
7
FAIL
1. Check for errors on TONE-BD or TONE-PT. If there are
errors, take the appropriate actions.
2. If the Reflective Loop Around Test fails for all ports on a
circuit pack, a -5 volt power problem is indicated. If a
TN736 or TN752 power unit circuit pack is present, check
the circuit pack for a red LED. If the red LED is on, then
replace the appropriate power unit circuit pack. If neither
the TN736 nor the TN752 power unit circuit pack is
present, then the OLS631DB AC power unit may be
defective. The system may contain a TN736 or TN752
power unit circuit pack OR an OLS631DB AC power unit,
BUT NOT BOTH TYPES OF POWER UNITS.
NOTE:
To investigate problems with an OLD631DB AC power
source, refer to CARR-POW Maintenance
documentation.
3. Rerun the test.
4. If the test fails again, replace the circuit pack.
PASS
CO Trunk Loop Around and Conference Test is successful.
User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external
wiring.
Table 10-226.
TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...