i. This is the resulting code that is generated when the link between the
circuit pack and the data module is successfully reset. The link is normally
reset when the circuit pack associated with an administered port is first
plugged in (assuming that the data module is already in place and
connected to the associated port), when a port is first administered
(assuming the associated circuit pack is plugged in and that the data
module is connected to the associated port), or when a data module is first
connected to an administered port. No system technician action is
necessary.
j. This warning off-board alarm occurs only for G3iV1.1-286 or G3iV2-386.
The alarm occurs when it appears to the system that a DCP endpoint has
been disconnected.
k. A DCP endpoint may have been disconnected.
l. This endpoint is part of processor link. Link initialization has failed (or
demand test for #183 for PI links has failed) and is indicating the
associated PDM as the cause. Check the PDM, the wiring to the PDM and
the link to the far end (i.e. AUDIX DCS, etc.) to resolve the problem.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Data Module
Internal Loop Around Test, for example, you may also clear errors generated from
other tests in the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Data Module Internal Loop Around Test (#175)
X
ND
Network Processing Element Crosstalk Test (#9)
X
ND
Information and Control Channel Loop Around Test
(#13)
X
ND
Data Module Audits Test (#17)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...