
Maintenance Object Repair Procedures
555-233-123
10-1782
Issue 4 May 2002
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use display time to display the time of day. If the time of day is displayed
correctly, wait 15 minutes and verify that the alarm is retired. If the alarm
has not been retired, continue with Step 3.
3. Test the active TN1648 SYSAM circuit pack using test maintenance [a | b]
sh. If any tests fail, refer to the repair procedures for the SYSAM circuit
pack before further investigating time-of-day problems. If all tests PASS
and the alarm has not been retired, proceed to Step 4.
4. Replace the active TN1648 SYSAM circuit pack must be replaced. See
“Replacing SPE Circuit Packs” in Chapter 5. The alarm should be resolved
within 15 minutes of replacing the SYSAM and resetting the time with set
time.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...