TIME-DAY (Time of Day)
Issue 4 May 2002
10-1781
555-233-123
TIME-DAY (Time of Day)
The time of day contains the current year, month, day of the week, day of the
month, hour, minute, and second. The Time of Day maintenance object is
responsible for monitoring the time-of-day clock and raising an alarm if the
time-of-day clock is not set or cannot be read by the software. If the time-of-day
clock is not set or cannot be read by the software, many features such as
Time-of-Day Routing, CDR, ISDN Call-by-Call, Duplication, and so on will be
either inoperative or incorrect. The time-of-day clock should be set using the set
time command whenever the system is initially powered up or the TN1648
SYSAM circuit pack is replaced.
The time-of-day clock can be read with the display time command and set via the
set time command. The time-of-day clock resides on the TN1648 SYSAM circuit
pack and has a backup battery to save the time of day during power failures. If the
TN1648 SYSAM circuit pack is physically removed from the carrier, the contents
of the time-of-day clock is lost and the time of day must be set when the TN1648
SYSAM circuit pack is re-inserted.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To
Run
Full Name of MO
TIME-DAY
MINOR
set time
Time of Day
Table 10-653.
Time of Day Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
Any
display time
247
1
1
This error indicates that software cannot read the time-of-day clock on the TN1648 SYSAM circuit
pack. During this condition, all time stamps on Alarm Log entries, Hardware Error Log entries,
and Software Error Log entries are potentially inaccurate. In addition, any features that are
sensitive to the time of day (such as SMDR, Time-of-Day Routing, ISDN Call-by-Call) will not
function correctly.
0
none
MINOR
OFF
set time
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...