TAPE (Tape Unit) [G3iV1.1-286]
Issue 4 May 2002
10-1613
555-233-123
Notes:
a. Run the Short Test Sequence first. If all tests pass, run the Long Test
Sequence. Refer to the appropriate test description and follow the
recommended procedures.
b. Error 1 indicates that the tape unit does not recognize that a cartridge is
inserted into the tape drive. If, in fact, there is no cartridge in the drive, the
problem can be corrected by simply inserting a cartridge. Follow the
directions given in “Error Type #1 - Repair Procedure.”
If there is a tape cartridge inserted into the tape drive, the problem is that
certain tape or tape drive failures may cause the tape drive to erroneously
report “missing tape” errors (tape Error Type #1 OR Aux Data value 9024).
Since this error may be the result of a problem with either the tape or the
tape drive unit, the tape cartridge should be replaced first. If the problem
persists, the tape unit should be replaced. When this error is first detected,
follow “Error Type #1 - Repair Procedure.”
Error Type #1 - Repair Procedure:
1. Replace the tape cartridge (if one exists) in the tape unit associated
with this error with a new tape cartridge.
2. Issue the test tape [a/b] repeat 2 command for the tape drive unit
that has the error.
3. If all the tests pass, assume that the problem has been resolved.
If some of the tests fail, resolve the corresponding errors, and repeat
step #2.
4. If translations have not already been saved onto the new tape, issue
the save translations command.
5. If the system contains recorded announcements, issue the save
announcements command.
3843 (l)
Any
Save the Translations
MINOR
OFF
save translation
3984(m)
Any
Save Translations
MINOR
OFF
save translation
10498 (n)
0
Save the Translations
10508 (o)
0
Save the Translations
Tape Unit Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...