EXT-DEV ADMIN? Y (External Device Alarm)
Issue 4 May 2002
10-825
555-233-123
2029
2100
2319
2320
2500
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
ANY
FAIL
The External Device Alarm has been activated by the external
device.
1. Clear the major alarm on the external device, and rerun
the test.
2. If the test still fails, then disconnect the External Device
Alarm Leads from the Maintenance circuit pack and rerun
the test.
3. If the test still fails, then there is a problem with the analog
external device alarm port or the Maintenance circuit pack
that is reporting the alarm. This circuit pack should be
replaced. There are failures that can occur on the
Maintenance circuit pack that will not be detected by their
respective maintenance, but which will cause many
environment tests to fail. If many environment tests are
failing, the suspect circuit pack should be replaced and
the test rerun.
Table 10-301.
TEST #120 External Device Alarm Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page