DATA-CHL (Data Channel)
Issue 4 May 2002
10-493
555-233-123
1006
ABORT
For this test, an Error Code of 1006 can have one of several
different meanings:
a. No other DATA-CHLs are administered and, therefore,
not available to place the call to the target DATA-CHL.
b. All other DATA-CHLs are busy and, therefore, not
available to place the call to the target DATA-CHL.
c. Could not allocate the necessary system resources to run
this test.
d. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if no other DATA-CHLs are administered (list
data-module).
2. If no other DATA-CHLs are administered, administer at least
one.
3. Determine if errors exist on links using target DATA-CHL
(status link).
4. If there are no errors, busyout the links (busyout link).
5. Retry the command at 1-minute intervals, up to 5 times.
6. Restore any busied out links.
1016
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
1018
ABORT
Test disabled through software patch.
2003
ABORT
Internal system error
2004
ABORT
Internal system error
1. Check dial plan to ensure data channel extensions are set up
as local extensions rather than remote or UDP extensions.
2. Retry the command at 1-minute intervals, up to 5 times.
Table 10-181.
TEST #109 Data Channel Remote Maintenance Loop Around
Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...