Maintenance Object Repair Procedures
555-233-123
10-152
Issue 4 May 2002
Table 10-50.
TEST #212 Clock Match Inquiry Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response to the test request was not received within the
allowable time period. If Error Type 1538 is present in the Error
Log, follow the maintenance strategy recommended for this
Error Type.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Test failed. Announcements recorded or played back while the
clock circuitry is not functioning properly sound distorted. The
ANN-BD may be defective or the Active Tone-Clock circuit
pack (TONE-BD) in the same Port Network as the ANN-BD
may be marginal and is causing this test to fail.
1. Reset the circuit pack via the reset board PCSS
command and then run this test again. If the test continues
to fail, proceed to Step 2 or 3 as applicable.
2. If this is a High or Critical Reliability system, determine the
Active TONE-BD in this Port Network via the status
system command and make the Standby Tone-Clock
circuit pack active via the set tone-clock PCSS
command. Rerun the test. If the test passes, then replace
the now Standby Tone-Clock circuit pack. If the test
continues to fail, replace the ANN-BD circuit pack.
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. See “General Notes” near the
beginning of this Maintenance procedure.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...