Maintenance Object Repair Procedures
555-233-123
10-936
Issue 4 May 2002
Figure 10-35.
ISDN-PRI Signaling Link Port Interactions (24-Channel)
Error Log Entries and Test to Clear Values
Table 10-342.
ISDN-PRI Signaling Link Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1 (c)
18
0
busyout port
PCSSpp (c)
WARNING
OFF
release port PCSSpp (c)
130 (a)
None
WARNING
ON
test port PCSSpp sh (c)
1537 (b)
NPE Crosstalk
Test #6
MINOR
ON
test port PCSSpp l r 3 (c)
(PORT 1)
TDM
BUS
SIGNALING
(PORT 24)
(PORT 23)
VOICE OR DATA
VOICE OR DATA
(PORT 2)
VOICE OR DATA
ISDN-LNK
ISDN-TRK
ISDN-TRK
ISDN-TRK
PI-LINK
PROCESSOR
(TN773/TN786)
PI
CIRCUIT
PACK
(TN765)
DS1/UDS1
CIRCUIT
PACK
INTERFACE