EXP-INTF (Expansion Interface Circuit Pack)
Issue 4 May 2002
10-787
555-233-123
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
FAIL
Loop back on TDM Bus A failed. Loop back on TDM Bus B
passed.
2
FAIL
Loop back on TDM Bus B failed. Loop back on TDM Bus A
passed.
3
FAIL
Loop back on both TDM Busses failed.
12
FAIL
Loop back on TDM Bus B failed. Loop back TDM Bus A aborted
because the system could not allocate time slots.
21
FAIL
Loop back on TDM Bus A failed. Loop back on TDM Bus B
aborted because the system could not allocate time slots.
FAIL
The test tone was not detected correctly after being looped
through the Expansion Interface circuit pack.
1. If error type 2305 has been logged against the Expansion
Interface circuit pack in the last 5 minutes, this test could
have failed due to the associated slips. If this is the case, first
resolve the 2305 error, and then repeat test.
2. Run the tests for the Active Tone-Clock on the Port Network
that contains the indicted Expansion Interface circuit pack to
verify that dial-tone is being supplied.
3. If the tone-clock is healthy, repeat the short test on the
Expansion Interface circuit pack.
4. If this test continues to fail, replace Expansion Interface
circuit pack.
Table 10-291.
TEST #240 EI Local Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...