Maintenance Object Repair Procedures
555-233-123
10-116
Issue 4 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute
intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to determine
the service state of the port.
3. If the port is in use, wait until the port is idle before testing.
Retry the command at 1-minute intervals no more than 5
times.
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.
1018
ABORT
Administration has disabled the test. The default for the
Test?
field on the station form is y. Determine why this field
has been set to n on this station (this may be due to the
ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested,
enter change station extension.
2. Change the
Test?
field on the station form to y.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run test are not available. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
Table 10-38.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...