Maintenance Object Repair Procedures
555-233-123
10-404
Issue 4 May 2002
Receive FIFO Overflow Error Counter Test (#596)
This test is non-destructive. When the CLAN circuit pack detects packet bus
buffer overflow, it increments the error on the FIFO Overflow error counter. This
test reads and clears the counter.
If errors are:
Then they may be due to:
Occasional
Statistical buffer sizing
Persistent
Circuit pack congestion that requires redistribution of traffic load
Table 10-149.
TEST #596 Receive FIFO Overflow Error
Counter Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If the problem persists, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run test.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1-10
FAIL
Circuit pack detects overflow errors. The error code indicates the
value of the on-board error counter.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test
(#598) (test board UUCSS).
3. If Packet Interface Test (#598) fails, refer to Packet Bus repair
procedures.
PASS
Circuit pack detects no errors.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...