STBY-SPE (Standby SPE)
Issue 4 May 2002
10-1529
555-233-123
q. Error Type 803 is logged when the upgrade software command failed due
to the failure to insert the translation card-mem into the Standby SPE in
time during the reboot immediately following a successful upgrade. This
implies that the Standby SPE is running the new software while the Active
SPE is still running the old software.
The translation card-mem should be inserted into the Standby SPE at the
appropriate time so as to allow the upgrade software command to be
re-executed.
r. Error Type 804 is logged when the upgrade software command failed due
to a loss of communication with the Standby SPE during the reboot
immediately following a successful software upgrade. This implies that the
communication path between the Active SPE and the Standby SPE may
not be functional.
Issue the test duplication-interface a and the test duplication-interface
b commands. If the tests pass, re-execute the upgrade software
command.
s. Error Type 805 is logged when the upgrade software command failed due
to the failure to insert the software card-mem in the Active SPE in time.
The software card-mem should be inserted into the Active SPE at the
appropriate time so as to allow the upgrade software command to be
re-executed.
t. Error Type 806 is logged when the upgrade software command failed due
to a bad flash checksum on the new Standby SPE after an upgrade of the
old Standby SPE and SPE-Interchange. This implies that the on-board
flash memory may not be functional. The behavior of the Standby SPE may
unpredictable.
The upgrade software command should be re-executed. If the command
fails again, the Standby SPE Processor circuit pack should be replaced.
u. Error Type 807 is logged when the upgrade software command failed due
to the failure to insert the translation card-mem into the new Standby SPE
after an upgrade of the old standby SPE and SPE-Interchange.
The translation card-mem should be inserted into the Standby SPE.
v. Error Type 808 is logged when the upgrade software command failed due
to the loss of communication with the new Standby SPE during an upgrade
following the upgrade of the old standby SPE and SPE-Interchange. This
implies that the programming of the Standby SPE never completed.
Use the “Special Upgrade Procedure” to re-execute an upgrade on the
Standby SPE only. If the upgrade fails again, the Standby SPE Processor
circuit pack should be replaced.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...