EXT-DEV ADMIN? N (External Device Alarm)
Issue 4 May 2002
10-821
555-233-123
2029
2319
2320
2500
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
ANY
FAIL
The External Device Alarm has been activated by the external
device.
1. Clear the major alarm on the external device, and rerun
the test.
2. If the test still fails, then disconnect the External Device
Alarms from the Maintenance circuit pack and rerun the
test.
3. If the test still fails, then there is a problem with the
Maintenance circuit pack that is reporting the alarm. This
circuit pack should be replaced. There are failures that can
occur on Maintenance circuit pack’s that will not be
detected by their respective maintenance, but which will
cause many environment tests to fail. If many environment
tests are failing, the suspect circuit pack should be
replaced and the test rerun.
PASS
If there is a problem with the external device, but the
Maintenance circuit pack connected to the device reports no
alarm, then the External Device may not be properly reporting
the problems or the External Device may not be properly
connected to the External Device.
Table 10-299.
TEST #120 External Device Alarm Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...