Maintenance Object Repair Procedures
555-233-123
10-1952
Issue 4 May 2002
Invalid LAPD Frame Error Counter Test (#597)
This test is non-destructive.
The VAL circuit pack detects invalid frames when it receives
■
a frame with a CRC error
■
an unrecognizable frame
■
a recognizable frame in an unexpected state
When the VAL circuit pack detects an invalid LAPD frame, it increments the
Invalid LAPD Frame error counter. This test reads and clears the counter, and
verifies the repair of the problem.
Errors can indicate a
■
circuit pack problem
■
packet bus problem
■
problem with another circuit pack on the bus
Table 10-697.
TEST #597 Invalid LAPD Frame Error Counter Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the problem persists, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
2500
ABORT
Internal system error.
Retry the command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...