Maintenance Object Repair Procedures
555-233-123
10-330
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery & Battery
Charger Query Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Cabinet Sensors Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment P sh r 1
1
Any
Cabinet Temperature
Query Test (#122)
MINOR
ON
test environment P sh r 3
257
Any
Cabinet Temperature
Query Test (#122)
MAJOR
ON
test environment P sh r 3
Table 10-128.
System Technician-Demanded Tests: CABINET
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive, ND = Non-destructive
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
Power Unit Query Test (carrier E) (#127) (c)
X
X
ND
Power Unit Query Test (carrier D) (#127) (c)
X
X
ND
Power Unit Query Test (carrier A) (#127) (c)
X
X
ND
Power Unit Query Test (carrier B) (#127) (c)
X
X
ND
Power Unit Query Test (carrier C) (#127) (c)
X
X
ND
Emergency Transfer Query Test (#124) (d)
X
X
ND
Cabinet Temperature Query Test (#122)
X
X
ND
External Alarm Lead Query Test (#120) (e)
X
X
ND
Analog Ring Generator Initialization Test (#117) (f)
X
X
ND
Analog Ring Generator Query Test (#118) (f)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...