Hybrid Line Remote Digital Loop Around Test
(#59)
This test checks the digital control pair from the port circuit to the terminal. The
on-board microprocessor sends a message to the terminal and checks for a
proper return message. This test is repeated three times, with two out of the three
attempts passing being sufficient for this test to pass. [G1] This test will run if the
station is in-service or out-of-service.
Table 10-328.
TEST #59 Hybrid Line Remote Digital Loop Around Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals for a maximum
of 5 times.
1
ABORT
A request for a remote station audit aborted even though all
internal resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for
this port. If this error type is present, release the port via
release port PCSSpp or release station extension, and
then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum
of 5 times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
PCSSpp to determine the station extension number of the
port. Use status station to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the “Status
Commands” section in Chapter 10, “Maintenance Commands
and Trouble-Clearing Aids” for a full description of all possible
states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a maximum of
5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...