Maintenance Object Repair Procedures
555-233-123
10-1766
Issue 4 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present, or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
1004
ABORT
(Non-TN497 circuit packs only.) The port was seized by a
valid call during the test. The test has been aborted. Use
display trunk xx to determine the trunk group/member
number of the port. Use status trunk to determine the service
state of the port. If the service state indicates that the port is in
use, the port is unavailable for certain tests. (Refer to the
“Status Commands” section in
Commands and Trouble-Clearing Aids’’
for a full description of
all possible states.) You must wait until the port is idle before
retesting.
1018
ABORT
The test has been disabled via administration.
Verify that the 'Maintenance Test' field on the 'Trunk Group'
form is set to 'n'. To enable the test, issue the 'change
trunk-group x' command (x equals the number of the trunk
group to be tested). Then, change the entry in the
'Maintenance Test' field on the form to 'y'.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-648.
TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...