Maintenance Object Repair Procedures
555-233-123
10-46
Issue 4 May 2002
■
40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, use
test port PCSSpp and follow the procedure for Test #48.
■
40977 indicates that no terminal equipment was connected when
ringing was attempted. Run the short test via the test port PCSSpp
command, and follow the procedure for the results of Test #48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11-minutes. To clear the error, reseat or replace
the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog circuit pack in the
system has this problem, then replace the circuit pack. If only analog circuit
packs on a particular carrier have this error, then the ringing generator may
not be connected to this carrier. If analog circuit packs on many carriers
have this error, then it is probably a problem with the ringing generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the customer or the terminal equipment,
disable it by setting the
Tests
field on the change station extension form
to
n
. On some software releases, this will also disable Tests #6, 7, 161, and
35.
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate tests in the order presented in the table below when inspecting errors.
By clearing error codes associated with the Battery Feed Test, for example, you
may also clear errors generated from other tests in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Battery Feed Test (#35)
X
X
ND
Station Present Test (#48)
X
X
ND
Looparound Test (#161)
X
ND
Conference Test (#7)
X
ND
NPE Crosstalk Test (#6)
X
ND
Station Status and Translation Audits and Updates Test (#36)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...