Maintenance Object Repair Procedures
555-233-123
10-862
Issue 4 May 2002
6. At the SAT type get boot-image <UUCSS> and press
RETURN
to check the
status of the firmware images on the target circuit pack.
The Display Firmware Image(s) report (
) appears.
Screen 10-16.
Display Firmware Image(s) screen
7. Ensure that both the
Active Image
and the
Reset Image
fields are as
you expect.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 257 — a log only error indicating that a certain software
resource was not available. Such an error very seldom occurs and usually
produces a proc_err. However, in the firmware download feature, the file
cannot be downloaded and/or the schedule can also abort/fail. To resolve
the error, use the test firmware download command. The Aux Data
specifies the error that resulted from the resource not being available. See
for more details.
Table 10-307.
FW-DWNLD Maintenance Error Log Entries
Error
Type
Aux
Data
Cause Of Error
Alarm
Level
On/
Off
Board
Test to Clear Value
257(a)
See note
Download failure
MINOR
OFF
test firmware download UUCSS
258(b)
See note
Download failure
MINOR
OFF
test firmware download UUCSS
259(c)
See note
Download failure
MINOR
OFF
test firmware download UUCSS
513(d)
See note
Download failure
MINOR
OFF
test firmware download UUCSS
796(e)
See note
Firmware
download request
MINOR
OFF
test firmware download UUCSS
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 01
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: No Yes
Reboot Image: No Yes
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...