ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 4 May 2002
10-87
555-233-123
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. These are in-line errors and can only be resolved over time.
■
40960
—
indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
■
40975
—
indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
Table 10-31. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960
40975
40977
None
15 (b)
Any
Audits and Updates
Test (#36)
18
0
busyout station
<extension>
WRN
OFF
release station <extension>
130(c)
None
WRN
ON
test port PCSSpp sh
257 (d)
Station Present Test
(#48)
WRN
OFF
test port PCSSpp sh r 3
513
Battery Feed Test
(#35)
MIN/
WRN
2
2
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
ON
test port PCSSpp sh r 2
769 (e)
Loop Around and
Conference Test(#47)
test port PCSSpp l r 3
1025
NPE Crosstalk Test
(#6)
MIN/
WRN
2
ON
test port PCSSpp l r 3
1281 (f)
1793 (f)
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...