CONFIG (System Configuration)
Issue 4 May 2002
10-465
555-233-123
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion
and removal of circuit packs in the system. When Switch Control detects that a
circuit pack is present in a port slot, it informs System Configuration and System
Configuration queries the circuit pack to determine the type and vintage of the
circuit pack. Similarly, when Switch Control detects that a circuit pack has been
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates that a Port circuit pack in the system did not respond to
a circuit pack type inquiry. Follow the procedures outlined in (b) to
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circuit pack in the system did not respond to
a vintage inquiry.
As a result of either of these errors, a Port circuit pack may be physically
inserted in a Port slot, but the system may not recognize its existence. The
Error Type and Aux Data fields specify the location of the port circuit pack
that caused the error as indicated in Table 10-100. If the Error Type field is
greater than 1000, subtract 1000 from the Error Type field before
consulting the table.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
CONFIG
none
none
System Configuration
System Configuration Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
none
2-117(a)
0-2
none
257(b)
none
1002-1117(c)
0-2
none
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...