Maintenance Object Repair Procedures
555-233-123
10-928
Issue 4 May 2002
NIC Query Test (#1383)
This test is non-destructive.
This test passes if the Ethernet port is connected and you can talk on the network.
Otherwise it fails with no fail code or AUX data.
Table 10-339.
TEST #1383 NIC Query Test
Error
Code
Test
Result
Description/Recommendation
None
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1015
ABORT
Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
FAIL
The Ethernet port is not connected and you cannot talk on the
network.
PASS
The Ethernet port is connected and you can talk on the network
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct.
Administer the MedPro interface if it is not already
administered.
2. If the board was already administered correctly, check
the error log to determine whether the board is
hyperactive. If this is the case, the board is shut down.
Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step
1, then issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and
the port.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...