MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
MTP Manager I Loop Around Test (#228)
This test is a nondestructive test. The test places the Manager I channel of the
MTP into a loop around mode, and it verifies the data integrity of the channel.
Although the test is nondestructive, it causes loss of keyboard input from the PPN
Manager I.
Table 10-519.
TEST #106 MTP Sanity Handshake Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1000
ABORT
System software resources required to run this test are not
available.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the “long” option.
2. If the test continues to fail, replace the Processor circuit
pack.
PASS
The MTP responded to the Sanity Handshake Query.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...