Reliability Systems: A Maintenance Aid
555-233-123
6-14
Issue 4 May 2002
Regardless of the condition that initiates an SPE-interchange, the G3MT is always
logged off as a result of the SPE-interchange. The G3MT is available to log into
after the SPE-interchange is complete and the “login” prompt is displayed.
Table 6-2.
Software-Requested Interchanges Caused by Alarm Conditions
Maintenance
Object
Alarm Level
On/Off
Board
Fault Severity
Level
Restart Level
STBY-SPE
WARNING
OFF
120
None
MEM-BD
MAJOR or MINOR
ON
110
Hot or Warm
1
1
If the Standby SPE is in Standby mode when the alarm occurs, a Hot SPE-Interchange occurs. If
the Standby is in Maintenance mode when the alarm occurs, however, a Warm SPE-Interchange
rather than a Hot SPE-Interchange occurs.
MEMORY
MAJOR or MINOR
ON
110
Hot or Warm
STBY-SPE
MAJOR
ON
100
None
PROCR
MAJOR
ON
70
Hot or Warm
SW-CTL
MAJOR
ON
65
Cold 2
MEM-CARD
MAJOR
OFF
65
Cold 1
DUPINT
MAJOR
ON
61
Hot
CARR-POW
MAJOR
ON
61
Cold 2
SHDW-CIR
MAJOR
ON or OFF
60
Warm
SHDW-LINK
MAJOR
ON
60
Warm
SW-CTL
MINOR
ON
40
Hot
PR-MAINT
MINOR
ON
30
Hot
PI-BD
MAJOR or MINOR
ON
20
Hot
PKT-CTRL
MAJOR
ON or OFF
20
Hot
PKT-CTRL
MINOR
ON or OFF
15
Hot
PI-PT
MAJOR
ON
15
Hot
DATA-CHL
MINOR
ON
15
Hot
DATA-CON
MINOR
ON
15
Hot
DATA-BD
MINOR
ON
15
Hot
CARD-MEM
MINOR
ON or OFF
10
Hot
PR-MAINT
MINOR
OFF
8
Hot
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...