Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-114
Issue 4 May 2002
Field descriptions
Defaults for data entry fields are listed in parentheses.
Product
Identification
10-digit number (starting with 1) that identifies the switch to an
Operations Support System (OSS), for example, INADS.
First OSS
Telephone Number
First telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. # and * are not allowed
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the first
OSS. (y)
Second OSS
Telephone Number
Second telephone number that the switch dials to report
alarms; must be obtained from the National Customer Support
Center (NCSC) or the TSC. # and * are not allowed
Abbrev Alarm
Report
Enables Abbreviated Alarm Report for the second OSS. (n)
display system-parameters maintenance Page 3 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
Modem Connection: external
Data Bits: 8
Parity: none
Modem Name:
RTS/CTS Enabled: \Q3
Auto Answer Ring Count (rings):
S0=10
Asynchronous Data Mode: &M0&Q0
Dial
Type: T
DTE Auto-Data Speed:
Adjustable Make/Break
Ratio:
Disable Data Compression:
Dial
Command: D
Enable Error Control:
No Answer
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...