Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-438
Issue 4 May 2002
Output
The following screen shows the output for test environment 1 to test a MCC/PPN
cabinet. The responses appear on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port
Port address (cabinet-carrier). For all but the CARR-POW
maintenance object, only the cabinet value is displayed. For the
CARR-POW maintenance object, both the cabinet and carrier
values display.
Maintenance
Name
The name of maintenance object
Alt. Name
Not applicable
Test No.
The test being executed.
Result
Test result: Pass, Abort, Fail, Disabled
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
test environment 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01 POWER 5 PASS
01 AC-POWER 79 PASS
01A CARR-POW 127 PASS
01B CARR-POW 127 PASS
01C CARR-POW 127 PASS
01D CARR-POW 127 PASS
01E CARR-POW 127 PASS
01 EMG-XFER 124 PASS
01 CABINET 122 PASS
01 EXT-DEV 120 PASS
01 RING-GEN 118 PASS
Command Successfully Completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...