ADX8D-PT (AUDIX Digital Port)
Issue 4 May 2002
10-17
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link. This is an off-board problem
that is detected by the port circuit. If this problem exists, replace the circuit
pack (see caution at the beginning of this section). Once the problem is
resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note (a).
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Use release port PCSSpp.
Table 10-7.
EMBEDDED AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1(a)
40987
None
WARNING
OFF
1(b)
1 to
20
None
WARNING
OFF
15(c)
Any
None
18(d)
0
busyout port
PCSSpp
WARNING
OFF
release port PCSSpp
23(e)
0
None
WARNING
OFF
130(f)
None
WARNING
ON
test port PCSSpp sh
257(g)
40971
None
513(h)
Any
None
1537(i)
40968
None
WARNING
OFF
1793
Voice & Ctrl. Local
Loop Test (#13)
MIN/WRN
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON
test port PCSSpp l r 3
2049
NPE Crosstalk
Test (#9)
MIN/WRN
2
ON
test port PCSSpp l r 3
2305(j)
40967
None
3840(k)
40965
None
3840(l)
41029
None
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...