test cdr-link
Issue 4 May 2002
8-425
555-233-123
Field descriptions
test cdr-link
The test cdr-link command validates that a call detail recording link has been
administered and established. The test defaults to “short”.
Parameters
Port
Port address (cabinet-carrier-slot-circuit): cabinet 1, carrier is A
(control carrier A in a simplex system) and either A or B (control
carriers A and B in a duplex system). The slot and circuit fields in
the port address for the CAP-MEM, and CARD-MEM maintenance
objects are always blank. The port address for maintenance object
FL-DATA is blank.
Maintenance
Name
The name of maintenance object being tested:
■
CARD-MEM for the memory card
■
CAP-MEM for memory card capacity
■
FL-DATA for the data consistency stored in memory cards
(duplicated switch)
Test No
The test being executed
Result
Test result: Pass, Fail, or Abort
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test cdr-link
primary | secondary
[short | long] [repeat number | clear] [schedule]
[primary |
secondary]
A system may have up to two CDR links: a primary that is normally
used and a secondary that serves as a backup in case the primary
fails. This qualifier specifies which link to test. Primary is the default.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...