Maintenance Object Repair Procedures
555-233-123
10-1452
Issue 4 May 2002
Table 10-550.
TEST #11 Digital Line Electronic Power Feed Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1000
ABORT
System resources required to run this test are not available. The
port may be busy with a valid call. Enter display port UUCSSpp
to determine the station extension or attendant number of the
port. Use status station or status attendant to determine the
service state of the port. If the port is in use, wait until the port is
idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
PASS
Electronic Power Feed Test passed. The message to turn on the
power to the station was successfully sent to the port.
1. Although this test will never actually return a FAIL
result except for the Internal system error described
above, it will log an error indicating the real results of
the test. Check the Error Log for any entries with Error
Types 767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, the test
sensed no problems with the power to the station. To
verify that the station is powered up correctly, run a
self-test on the station and check that all the feature
buttons are operating.
3. If Error Type 769 appears in the Error Log, this
indicates some problem with the power to the station.
Check for a short in the wiring, a damaged jack, a
defective voice terminal, or an incorrect type of
terminal.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...