
Maintenance Object Repair Procedures
555-233-123
10-2010
Issue 4 May 2002
Ringing Application Test (#51)
This test checks the ringing application circuitry common to all ports on an Analog
Line circuit pack.
Table 10-722.
TEST #51 Ringing Application Circuit Test
Error
Code
Test
Result
Description/Recommendation
1000 or
2100
ABORT
Could not allocate the necessary system resources to run
test.
ABORT
Could not allocate the necessary system resources to run
test. The circuit pack is not installed. Internal System Error.
2000
ABORT
There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error
log, follow the maintenance strategy that is
recommended for this error type.
2. Run the busyout board, reset board, and release busy
board commands, and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there
are no problems found, replace the circuit pack.
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use, the port is
unavailable for certain tests. (Refer to the “Status
Commands” section in
Chapter 8, ‘‘Maintenance Commands
for a full description of all
possible states.) You must wait until the port is idle before
retesting.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is idle, escalate
the problem.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...