
FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-833
555-233-123
17
FAIL
The translations and announcements are different in both
SPEs. The Active SPE has the most current translations
and the Standby SPE has the most current
announcements.
18
FAIL
The translations and announcements are different in both
SPEs. The standby SPE is the most current.
1. Follow the procedures for Error Code 9.
20
FAIL
The load vintages and announcements are different in both
SPEs. The Standby SPE has the most current
announcements.
21
FAIL
The translations, announcements, and load vintages are
different in both SPEs. The Active SPE has the most
current translations and the Standby SPE has the most
current announcements.
22
FAIL
The translations, announcements, and load vintages are
different in both SPEs. The Standby SPE has the most
current translations and announcements.
1. Follow the procedures for Error Code 4. Be sure to
issue the save announcements command.
32
FAIL
The update files are different in both SPEs. The update file
on the Active SPE is most current.
1. Have INADS issue the copy update-file command. If
the update file copy passes, go to Step 2.
2. Reissue test card-mem long to resolve the alarms.
33
FAIL
The update files and translations are different in both
SPEs. The Active SPE has the most current update file and
translations.
34
FAIL
The update files and translations are different in both
SPEs. The Active SPE has the most current update file,
and the Standby SPE has the most current translations.
1. Issue the save translations command to save
translations on both SPEs.
2. Have INADS issue the copy update-file command to
copy the update file from the Active to the Standby
SPE.
3. Reissue test card-mem long to resolve the alarms.
36
FAIL
The update files and load vintages are different in both
SPEs. The Active SPE has the most current update file.
Table 10-303.
TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...