Control Channel Loop-Around Test (#52)
This non-destructive test fails if the circuit pack does not return to a sane state
after being reset. This test queries the circuit pack for its code and vintage, and
verifies its records.
Table 10-146.
TEST #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description/Recommendation
None
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
FAIL
The circuit pack failed to return the code or vintage.
1. Retry command at 1-minute intervals, up to 5 times.
2. Reset the board (reset board UUCSS).
3. If reset aborts with error code 1115, busyout (busyout
board UUCSS), reset (reset board UUCSS), and release
board (release board UUCSS).
4. If test continues to fail, replace the circuit pack.
5. Escalate the problem if failures continue.
PASS
Test successful.