BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-301
555-233-123
m. Certain ISDN-BRI cause codes are logged by switch software. The cause
code can be determined from the following formula:
If the error type is greater than 3968, then the ISDN-BRI cause code is
equal to the error type minus 3968. This code was sent to the endpoint by
the switch.
If the error type is less than 3968, then the ISDN-BRI cause code is equal
to the error type minus 3840. This code was sent to the switch by the
endpoint.
A description of the various ISDN-BRI cause values is contained in Table
10-65. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the Avaya ISDN-BRI Specification (801-802-100). In addition, the Aux Data
field of the Error Log entry contains additional diagnostic information.
n. Error 3847 indicates that sets on the port do not support level 3
initialization. Consult the Set Service documentation
Service or Option
Not Implemented
79
Service or Option
Not Implemented
Requested service or option (or combination of
selected options) is not supported (implemented)
in switch or the adjunct.
1. Consult switch and adjunct documentation to
determine ASAI service and options
supported by both switch and adjunct.
Readministration of the switch-administered
capabilities (see Customer Optional Feature
Form) or those of the adjunct may be
necessary to correct the problem.
2. If Step 1 does not provide the set of desired
services due to deficient implementation,
escalate the problem to the next tier.
Switch Error
Conditions
87
Internal Switch
Audit
There is an inconsistency in switch data records.
1. There is no action needed since the switch
has corrected the data inconsistency.
2. If a number of these errors continue to occur,
then escalate to next tier.
Table 10-119.
ASAI Cause Values — Continued
Code
Explanation
Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...