Maintenance Object Repair Procedures
555-233-123
10-612
Issue 4 May 2002
The TN767E circuit pack combined with 120A1 CSU Module forms an Enhanced
Integrated CSU. The new 120A1 CSU Module, when combined with the
functionality provided by the TN767E hardware and firmware, and new switch
software, provides functionality equivalent to an external stand-alone ESF T1
CSU. The 120A1 CSU Module connects to the TN767E circuit pack on the I/O
connector panel on the back of the port carrier. The new CSU Module, thus
becomes an integrated part of the DEFINITY system. Throughout the document,
the term 120A1 will mean a 120A1 or later suffix CSU Module.
The Enhanced Integrated CSU is for use in the United States of America with
1.544 Mbps DS1 service.
The TN767E and 120A1 CSU Module support on-demand loopback tests that
assist in the detection of faults between the TN767E circuit pack and the CSU
Module, between the Integrated CSU and the optional Customer Premises
Loopback Jack, or between the Integrated CSU and remote CSU. These
loopback tests are explained in detail later in this DS1-BD section, but
gives a high level overview of the loopback points.
The following list of acronym definitions are for
■
PLB = Payload Loopback
■
BLB = Board Loopback
■
ELB = Equipment Loopback
■
LLB = Line Loopback
■
RLB = Repeater Loopback
■
CLJ = Loopback Jack Loopback
■
R-LLB = Remote Line Loopback
■
SMRT = Smart Jack
■
LPBK = Loopback
For more information about DS1 interfaces, see the DEFINITY Communications
System DS1/CEPT1/ISDN-PRI Reference, 555-025-107.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...