Maintenance Object Repair Procedures
555-233-123
10-1912
Issue 4 May 2002
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied
out to out-of-service.
1. Enter the busyout board UUCSS command to put all
trunks or ports of the UDS1 Interface circuit pack into the
out-of-service state.
2. Retry the command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the
system. Executing this test could cause major system
disruption.
If the UDS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit pack
or to the Tone-Clock circuit pack via the following command
sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch
command.
1950
ABORT
Another loopback/span test is already executing on the DS1
board or the board is in a network requested loopback mode
(Line loopback or Payload loopback). The hardware error log
will indicate whether a Customer Loopback Jack Test, Far CSU
Loopback Test, or the One-Way Span Test is executing or if the
board is in line loopback or payload loopback mode. Only one
long-duration loopback/span tests can be active at a given time.
Thus, if a loopback/span test is already active, that test must be
terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
1951
ABORT
The CSU Repeater Loopback Test could not be executed
because the 120A1 CSU Module or the 401A T1 Sync Splitter
was not physically installed. Physically connect the 120A1 CSU
Module or the 401A T1 Sync Splitter to the UDS1 board on the
back of the port carrier.
Table 10-684.
TEST #1211 CSU Repeater Loopback Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...