Maintenance Object Repair Procedures
555-233-123
10-1090
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The “clear” option can replace the “repeat” option in test memory. For a
High or Critical Reliability system, the carrier (a or b) must be specified. In
all other systems, there is no need to specify the carrier.
b. The Read All Memory Test (#85) failed. Refer to the FAIL section of this
test. The error is associated with MEM-BD 1.
c. The Memory Error Detection Test (#87) failed. Refer to the FAIL section of
this test. The error is associated with MEM-BD 1.
d. The Text Checksum Test (#86) failed. Refer to the FAIL section of this test.
The error is associated with MEM-BD 1 and is an ON board alarm.
e. There are Functional Test errors against both the Processor circuit pack
and Memory. This test is run only on the Standby SPE in a High or Critical
Reliability system. On other systems or on the Active SPE, the test is run
only via a reset system 4 or a reset system 5.
Table 10-410.
MEM-BD (Memory) Memory Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test memory a/b l r 1
1-256
Any
Read All Memory Test
(#85)
MAJOR
ON
test memory a/b l r 5
257-512 (b)
Any
Read All Memory Test
(#85)
MAJOR
ON
test memory a/b l r 1
513 (c)
0
Memory Detection/
Test (#87)
MAJOR
ON
test memory a/b r 3
769 (d)
Any
Text Checksum Test
(#86)
MAJOR
OFF/ON
test memory a/b l r 2
1025 (e)
Any
Memory Functional
Test (#332)
MAJOR
ON
test memory a/b l r 1
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...