Routine Maintenance Procedures
555-233-123
5-40
Issue 4 May 2002
Simplex Mode Test Procedure
To perform the Analog Tie Trunk Port Test in the simplex mode:
1. Repeat Steps 1 through 7 of the E & M Mode Test Procedure.
2. Set the dip (option) switches for each of the two ports to be tested on the
Tie Trunk circuit pack to simplex mode.
3. Enter add trunk n to add a new (test) trunk group. Then enter:
■
Group Type — tie
■
TAC — (use trunk access code obtained from dial plan)
■
Trunk Type (in/out) — wink/wink
■
Port — assign two of the ports from the tie trunk
■
Mode — simplex
■
Type — type 5
34
36
37
T7
38
R7
39
40
41
42
43
T8
44
R8
45
46
47
48
49
50
Table 5-6.
Carrier Lead Appearances at 110 Cross-Connect Field — Continued
110 Connecting Block
Terminals
CO Trunk TN747B
Tie Trunk TN760B
Continued on next page