MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1059
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate tests in the order they are presented in
. By clearing error
codes associated with the NPE Connection Audit Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 10-384.
System Technician-Demanded Tests
Order of Investigation
Apply to
TN802?
1
1
N = No; this test either passes or ABORTS with Error Code 2000 (problem with NT)
Short
Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
D/ND
2
2
D = Destructive; ND = Nondestructive
NPE Connection Audit Test (#50)
Y
X
ND
Control Channel Loop Test (#52)
Y
X
ND
Loss of Signal Alarm Inquiry Test
(#138)
N
X
X
ND
Blue Alarm Inquiry Test (#139)
N
X
X
ND
Red Alarm Inquiry Test (#140)
N
X
X
ND
Yellow Alarm Inquiry Test (#141)
N
X
X
ND
Major Alarm Inquiry Test (#142)
N
X
X
ND
Minor Alarm Inquiry Test (#143)
N
X
X
ND
Slip Alarm Inquiry Test (#144)
N
X
X
ND
Misframe Alarm Inquiry Test (#145)
N
X
X
ND
Translation Update Test (#146)
N
X
X
ND
SAKI Sanity Test (#53)
Y
X
D
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...