Maintenance Object Repair Procedures
555-233-123
10-1322
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals, a maximum of 3
times.
2500
ABORT
Internal system error
1. Retry the command.
NO
BOARD
The Packet Interface circuit pack is not detected as being
physically present.
1. Reboot the system, then retry the command. If the NO
BOARD indication persists, replace the TN2401/TN794
NetPkt circuit pack.
5001
FAIL
The TDM clock on the Processor Port Network has failed.
1. Refer to the TDM-CLK to clear this failure.
5002
FAIL
The Packet Bus on the Processor Port Network has failed.
1. Refer to PKT-BUS to clear this failure.
Any
Other
Than
Those
Listed
Above
FAIL
The Packet Interface diagnostic tests failed. If the system is
equipped with the High Reliability or Critical Reliability
Configuration, the reset will run only on demand if the Packet
Interface is on the standby SPE or if Packet Interface is in an
out-of-service state on the active SPE (which means an SPE
interchange was not allowed because the standby SPE is not
healthy). If the latter case is true, also refer to the repair
procedures for STBY-SPE for clearing the problem on the
standby SPE.
1. Retry the command reset packet-interface
2. If the reset fails, replace the TN2401/TN794 NetPkt circuit
pack.
PASS
The Packet Interface diagnostic software passed. The Packet
Interface is put back into service automatically.
Table 10-489.
TEST #889 Reset Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...