VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 4 May 2002
10-1943
555-233-123
f. Error Type 769: Logic error. By itself this error can be ignored, but it can
result in other error types being reported.
g. Error Type 1281,1290-1295: Critical hardware or firmware error.
Error Type descriptions are as follows:
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
h. Error Type 1537, 1796: A hyperactive VAL circuit pack that has exceeded
the error threshold has been removed from service.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
i. Error Type 1794: Packet bus transmit buffers have overflowed.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
j. Error Type 1798: Unable to write translation RAM.
1. Attempt to clear alarm (reset board UUCSS).
2. If alarm recurs within 15 minutes, replace the circuit pack.
k. Error Type 2049: Packet Interface Test (#598) failed.
1. Attempt to clear the alarm (test board UUCSS l r 3).
2. If alarm does not clear, reset the circuit pack (reset board UUCSS).
4355
ROM Checksum error
4356
Angel Message Corruption error
4357
Instruction set error
If the switch detects:
Then the switch:
1 error,
Resets circuit pack.
3 errors in 15 minutes,
Raises MINOR alarm.
1290
Global HDLC error
1291
Main RAM/ROM error
1292
CPU error
1293
Insane onboard processor
1294
Onboard translation RAM error
1295
(Aux 3) RSCL link down
(Aux 0) RSCL keep alive failure
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...