Maintenance Object Repair Procedures
555-233-123
10-182
Issue 4 May 2002
ASAI-PT
Unless otherwise stated, all maintenance actions contained in this section apply
to ASAI-PT and ISDN-BRI ports connected to ASAI adjuncts. This port type is
administered as an ASAI-BD on the TN800 circuit pack.
The TN800 circuit pack is a PC-based platform that allows interaction of multiple
applications with DEFINITY at any time. DEFINITY software (Native mode) will
support emulation of three types of port MOs on this board. The type of ports to be
emulated are defined by the applications running on the TN800. The TN800 can
support a maximum of 32 ports (time slots) at a time.
The TN800 connects to the switch through a single slot in the backplane, however
its width is not limited to one slot. The number of slots occupied by the TN800 is
supplied by the board during its insertion. The TN800 is 3 slots wide. The blank
(reserve) slots are to the left of the functional slot.
In non-native mode the TN800 is recognized as TN556, TN2181, TN754, or
TN746 based on the switch software and the application running on the TN800. In
non-native mode only one type of port MOs will run at any time, and the port type
depends on the application running on the TN800. If the TN800 fails diagnostics in
non-native mode, the system’s alarm and error logs would show a failure for the
board type the TN800 is emulating.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., and so forth).
Full Name of MO
ASAI-PT
MAJOR
2,3
2
The alarm level for ASAI adjunct ports may be administered using the set options
command. The alarm level can be set independently for off-board and on-board alarms
to WARNING, MINOR, or MAJOR for all ASAI adjunct ports in the system.
3
All alarming for an ASAI adjunct and off-board alarming for an ASAI port is disabled if the
ASAI adjunct asks the switch to suspend maintenance. When this occurs, an error and
a WARNING alarm is logged against the ASAI adjunct. Check the Hardware Error and
Alarm Logs to see if the adjunct has disabled alarming.
test port PCSSpp l
ASAI ISDN BRI Port
ASAI-PT
WARNING
test port PCSSpp l
ASAI ISDN BRI Port
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...