Maintenance Object Repair Procedures
555-233-123
10-598
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. Aux data 57376 - No loop current on incoming call
Aux data 57424 - No loop current on outgoing call
Table 10-222.
DIOD Trunk Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
15 (b)
any
Port Audit Update
Test (#36)
18
0
busyout trunk
<grp>/<mbr>
769 (a)
57392
None
MAJ/MIN/
WRN
2
2
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm
is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON
1537
Dial Tone Test (#0)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 2
1793
Loop Around and
Conference Test
(#33)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 3
2049
NPE Cross Talk
Test (#6)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 3
2561 (a, d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...